Skip to search boxSkip to navigationSkip to main content

The effect of holder design on the response of the HPA neutron personal dosemeter

*Corresponding author for this work
Research Output:
Contribution to journal
Article
Research
Peer-review

Abstract

Modifications to the holder of the HPA neutron personal dosemeter are proposed which make the etched surface of the dosemeter have an effective depth equivalent to 10 mm of ICRU 4-element tissue. The effect of these changes has been investigated using Monte Carlo modelling with the code MCNP5. These calculations have been used to determine the energy dependence of the reading per unit Hp (10) for the current and modified designs, with the resultant response characteristics then being folded with workplace field energy distributions to determine the success or otherwise of the proposed changes.

Research Output Information

Output type

Research Output:
Contribution to journal
Article
Research
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 1128-1131 (4 pages)

Journal (Volume, Issue Number)

Radiation Measurements (Volume 43, Issue 2-6)

Publication milestones

  • Published - 02/2008

Publication status

Published - 02/2008

ISSN

1350-4487

Publication IDs

  • Scopus: 46549084711