The effect of holder design on the response of the HPA neutron personal dosemeter
- Richard Tanner(corresponding author),
- ,
- ,
- National Radiological Protection Board
Research Output:
Contribution to journal
Article
Research
Peer-reviewAbstract
Modifications to the holder of the HPA neutron personal dosemeter are proposed which make the etched surface of the dosemeter have an effective depth equivalent to 10 mm of ICRU 4-element tissue. The effect of these changes has been investigated using Monte Carlo modelling with the code MCNP5. These calculations have been used to determine the energy dependence of the reading per unit Hp (10) for the current and modified designs, with the resultant response characteristics then being folded with workplace field energy distributions to determine the success or otherwise of the proposed changes.
Research Output Information
Output type
Research Output:
Contribution to journal
Article
Research
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 1128-1131 (4 pages)Journal (Volume, Issue Number)
Radiation Measurements (Volume 43, Issue 2-6)Publication milestones
- Published - 02/2008
Publication status
Published - 02/2008
ISSN
1350-4487Publication IDs
- Scopus: 46549084711