Skip to search boxSkip to navigationSkip to main content

Early Outcomes of Thoracic Endovascular Stent-Graft Repair for Acute Complicated Type B Dissection Using the Gore TAG Endoprosthesis

  • Benjamin J. Pearce
    ,
  • Marc A. Passman(corresponding author)
    ,
  • Mark A. Patterson
    ,
  • Steve M. Taylor
    ,
  • Christopher J. Lecroy
    ,
  • Bart R. Combs
*Corresponding author for this work
  • University of Alabama Hospitals
Research Output:
Contribution to journal
Article
Research
Peer-review

Abstract

We assessed the technical success and early outcome of thoracic endovascular aortic repair (TEVAR) for complicated acute type B thoracic aortic dissection treated at a single institution using a commercially available device. All patients with symptomatic complicated acute type B thoracic aortic dissection treated with TEVAR since Food and Drug Administration approval of the Gore (Flagstaff, AZ) TAG® endoprosthesis were identified from a prospectively maintained vascular registry. Clinical indications, operative technique, perioperative complications, follow-up imaging, and mortality were analyzed. Between March 2005 and November 2007, 127 TEVARs using the TAG endoprosthesis were performed, of which 15 (11.8%) were for complicated acute type B thoracic aortic dissection. Indications for repair were malperfusion (53%), persistent pain (27%), and primary aortic failure (33%). Technical feasibility and success with deployment proximal to the entry tear was 93.3%, requiring at least partial coverage of the left subclavian artery in seven (46.7%). Adjunctive procedures required at the time of TEVAR included renal stent (n = 2), iliac stent (n = 3), and access-artery open repair (n = 2). Twelve patients (80%) had immediate resolution of the malperfusion deficit. Major perioperative complications included paraplegia (13.3%), renal failure requiring hemodialysis (13.3%), and stroke (6.7%). Perioperative mortality was 13.3%, occurring in one patient presenting with rupture and one with profound heart failure on admission. For complicated acute type B thoracic aortic dissection, TEVAR using commercially available stent grafts showed high technical success, excellent results at resolving malperfusion, and acceptably low complications and perioperative mortality.

Research Output Information

Output type

Research Output:
Contribution to journal
Article
Research
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 742-749 (8 pages)

Journal (Volume, Issue Number)

Annals of Vascular Surgery (Volume 22, Issue 6)

Publication milestones

  • Published - 11/2008

Publication status

Published - 11/2008

ISSN

0890-5096

Publication IDs

  • Scopus: 55049111739
  • PubMed: 18922675