Skip to search boxSkip to navigationSkip to main content

Characterisation of an isotopic neutron source: A comparison of conventional neutron detectors and micro-silica glass bead thermoluminescent detectors

  • Y. M. Abubakar
    ,
  • M. P. Taggart(corresponding author)
    ,
  • A. Alsubaie
    ,
  • A. Alanazi
    ,
  • A. Alyahyawi
    ,
  • A. Lohstroh
*Corresponding author for this work
  • University of Surrey
    ,
  • Ahmadu Bello University
    ,
  • Taif University
    ,
  • Cancer Centre
    ,
  • Queen Alexandra Hospital
    ,
  • Sunway University
Research Output:
Contribution to journal
Article
Research
Peer-review

Open access

Abstract

As a result of their thermoluminescent response, low cost commercial glass beads have been demonstrated to offer potential use as radiation dosimeters, providing capability in sensing different types of ionising radiation. With a linear response over a large range of dose and spatial resolution that allows measurements down to the order of 1 mm, their performance renders them of interest in situations in which sensitivity, dynamic range, and fine spatial resolution are called for. In the present work, the suitability of glass beads for characterisation of an Americium-Beryllium (241AmBe) neutron source has been assessed. Direct comparison has been made using conventional 3He and boron tri-fluoride neutron detectors as well as Monte Carlo simulation. Good agreement is obtained between the glass beads and gas detectors in terms of general reduction of count rate with distance. Furthermore, the glass beads demonstrate exceptional spatial resolution, leading to the observation of fine detail in the plot of dose versus distance from source. Fine resolution peaks arising in the measured plots, also present in simulations, are interesting features which based on our best knowledge have previously not been reported. The features are reproduced in both experiment and simulation but we do not have a firm reason for their origin. Of greater clarity is that the glass beads have considerable potential for use in high spatial resolution neutron field characterisation, subject to the availability of a suitable automated TLD reader.

Research Output Information

Output type

Research Output:
Contribution to journal
Article
Research
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 497-501 (5 pages)

Journal (Volume, Issue Number)

Radiation Physics and Chemistry (Volume 140)

Publication milestones

  • Published - 11/2017

Publication status

Published - 11/2017

ISSN

0969-806X

Publication IDs

  • Scopus: 85007610558