Anomalously high excretion of Pu in urine following inhalation of plutonium nitrate?
- George Etherington(corresponding author),
- G. N. Stradling,
- Alan Hodgson,
- L. K. Fifield
- National Radiological Protection Board,
- Australian National University
Abstract
A study of the biokinetics of inhaled plutonium nitrate in two volunteers has been carried out. Low doses (∼ 80 μSv) were achievable because tracers of high isotopic purity were used: 237Pu (measurable by X ray spectrometry) and 244Pu (measurable by accelerator mass spectrometry). Lung retention, amount in blood, uptake to the liver and skeleton, and urinary and faecal excretion were measured. The measured urinary excretion rates are about a factor of three higher than those predicted from urine excretion data measured following intravenous injection of plutonium to the same volunteers. If similar biokinetic behaviour occurs in workers exposed to plutonium nitrate, intakes by inhalation and corresponding committed doses assessed by urine bioassay could be consistently overestimated by a similar factor.
Research Output Information
Output type
Original language
EnglishPages from-to (Number of pages)
Pages 321-324 (4 pages)Journal (Volume, Issue Number)
Radiation Protection Dosimetry (Volume 105, Issue 1-4)Publication milestones
- Published - 2003
Publication status
ISSN
0144-8420Publication IDs
- Scopus: 0141633007
- PubMed: 14526978
Sustainable Development Goals
- SDG 3 Good Health and Well