Adequacy of personal air samplers for monitoring plutonium intakes
- A. Birchall,
- A. C. James,
- C. R. Muirhead
- Public Health England
Abstract
When personal air samplers (PAS) are used to estimate plutonium intakes, the number of particles collected is often small, and substantial errors in the estimate can arise from random statistical error. By using a Gaussian approximation for the probability distribution of intake following a single PAS measurement, we have derived simple algebraic expressions for the probability that an estimated intake (or committed dose equivalent), from a series of PAS measurements, will be exceeded by any given factor F. A small computer program written in BASIC is listed in an appendix to aid evaluation. From these expressions, together with a definition of adequacy used by the ICRP, the aerosol conditions under which the PAS will give inadequate estimates of intake are defined.
Research Output Information
Output type
Original language
EnglishPages from-to (Number of pages)
Pages 179-188 (10 pages)Journal (Volume, Issue Number)
Radiation Protection Dosimetry (Volume 37, Issue 3)Publication milestones
- Published - 1991
Publication status
ISSN
0144-8420Publication IDs
- Scopus: 0025836117
Sustainable Development Goals
- SDG 3 Good Health and Well