Radon-222 entry rate in homes and workplaces determined with modern electronic radon detectors

  • Krasimir Mitev
  • , Vladislav Todorov
  • , Strahil Georgiev
  • , Philippe Cassette
  • , Benoit Sabot
  • , Zornitza Daraktchieva
  • , Stefan Röttger
  • , Ivelina Dimitrova*
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

1 Citation (Scopus)

Abstract

Radon is the second leading cause of lung cancer after smoking. While radon exposure is assessed by the annual average radon concentration, the radon entry rate, which is fundamental to understanding radon behaviour and mitigation, has received less attention due to measurement challenges. Technological advancements over the past decade have led to the development of affordable and widely available consumer-grade electronic detectors that can provide time-resolved radon measurements. A novel method for estimating the radon entry rate from radon time series measured by fast-response, consumer-grade electronic monitors is presented. It was validated through experiments conducted in a primary metrology laboratory and test-bed studies. It was implemented in a three-year radon monitoring campaign in 36 occupied dwellings and workplaces located in both radon-priority and non-priority areas. During the campaign data on the dynamics of radon entry rate and air change rate were gathered remotely without interrupting the buildings’ usage cycle. A correlation between the radon entry rate and the air change rate at low ventilation was observed in about 80% of the buildings, which demonstrates that the radon entry rate can be studied in relation to other dynamic parameters. This new approach can be used by scientists developing models for radon transport in buildings, as well as by remediation and mitigation professionals to provide smart and energy-efficient mitigation strategies. The method proposed herein provides insights into radon dynamics and can revolutionize our efforts to maintain a healthy indoor environment with respect to radon.

Original languageEnglish
Article number114190
JournalBuilding and Environment
Volume290
DOIs
Publication statusPublished - 15 Feb 2026

Bibliographical note

Publisher Copyright:
© 2026 The Author(s)

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Air change rate
  • Electronic radon detectors
  • Online monitoring
  • Radon entry into buildings
  • Radon in homes and workplaces
  • Radon-222

Fingerprint

Dive into the research topics of 'Radon-222 entry rate in homes and workplaces determined with modern electronic radon detectors'. Together they form a unique fingerprint.

Cite this