Foreign object detection and removal to improve automated analysis of chest radiographs

Laurens Hogeweg*, Clara I. Sánchez, Jaime Melendez, Pragnya Maduskar, Alistair Story, Andrew Hayward, Bram Van Ginneken

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

6 Citations (Scopus)

Abstract

Purpose: Chest radiographs commonly contain projections of foreign objects, such as buttons, brassier clips, jewellery, or pacemakers and wires. The presence of these structures can substantially affect the output of computer analysis of these images. An automated method is presented to detect, segment, and remove foreign objects from chest radiographs. Methods: Detection is performed using supervised pixel classification with a kNN classifier, resulting in a probability estimate per pixel to belong to a projected foreign object. Segmentation is performed by grouping and post-processing pixels with a probability above a certain threshold. Next, the objects are replaced by texture inpainting. Results: The method is evaluated in experiments on 257 chest radiographs. The detection at pixel level is evaluated with receiver operating characteristic analysis on pixels within the unobscured lung fields and an Az value of 0.949 is achieved. Free response operator characteristic analysis is performed at the object level, and 95.6% of objects are detected with on average 0.25 false positive detections per image. To investigate the effect of removing the detected objects through inpainting, a texture analysis system for tuberculosis detection is applied to images with and without pathology and with and without foreign object removal. Unprocessed, the texture analysis abnormality score of normal images with foreign objects is comparable to those with pathology. After removing foreign objects, the texture score of normal images with and without foreign objects is similar, while abnormal images, whether they contain foreign objects or not, achieve on average higher scores. Conclusions: The authors conclude that removal of foreign objects from chest radiographs is feasible and beneficial for automated image analysis.

Original languageEnglish
Article number071901
JournalMedical Physics
Volume40
Issue number7
DOIs
Publication statusPublished - Jul 2013
Externally publishedYes

Keywords

  • artifact restoration
  • CAD
  • chest radiography
  • detection
  • foreign objects
  • pixel classification

Fingerprint

Dive into the research topics of 'Foreign object detection and removal to improve automated analysis of chest radiographs'. Together they form a unique fingerprint.

Cite this