T1 - Fellow-eye comparison of posterior capsule opacification rates after implantation of 1CU accommodating and AcrySof MA30 monofocal intraocular lenses
AU - Hancox, Joanne
AU - Spalton, David
AU - Heatley, Catherine
AU - Jayaram, Hari
AU - Yip, Jennifer
AU - Boyce, James
AU - Marshall, John
N1 - Funding Information:
Supported by a grant from Alcon, Fort Worth, Texas, USA.
PY - 2007/3
Y1 - 2007/3
N2 - Purpose: To measure posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) capsulotomy rates between the AcrySof MA30 intraocular lens (IOL) (Alcon) and the 1CU IOL (HumanOptics) in a fellow-eye comparison. Setting: Ophthalmology Department, St. Thomas' Hospital, London, United Kingdom. Methods: Thirty patients who had bilateral cataract surgery with a 1CU IOL prospectively randomly allocated to 1 eye and an AcrySof MA30 monofocal IOL to the other eye were examined. Best corrected distance visual acuity was recorded using the Early Treatment Diabetic Retinopathy Study logMAR chart. Digital retroillumination images of the posterior capsule were taken with the pupil dilated and analyzed with POCO software. Results: Eyes with the 1CU IOL had significantly higher PCO rates than eyes with the MA30 IOL at all time points. By 2 years after surgery, 50% of eyes with a 1CU IOL had required Nd:YAG capsulotomy compared with no eyes with an MA30 IOL. There was no significant difference in visual acuity at any time point when post Nd:YAG capsulotomy was taken in to account. Conclusions: The 1CU IOL has 4 broad optic-haptic junctions where the square-edged barrier is breached; this appeared to allow passage of lens epithelial cells, leading to an increase in PCO. However, the increased PCO cannot be attributed to this alone as the 1CU is hydrophilic, a factor known to be associated with higher PCO rates.
AB - Purpose: To measure posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) capsulotomy rates between the AcrySof MA30 intraocular lens (IOL) (Alcon) and the 1CU IOL (HumanOptics) in a fellow-eye comparison. Setting: Ophthalmology Department, St. Thomas' Hospital, London, United Kingdom. Methods: Thirty patients who had bilateral cataract surgery with a 1CU IOL prospectively randomly allocated to 1 eye and an AcrySof MA30 monofocal IOL to the other eye were examined. Best corrected distance visual acuity was recorded using the Early Treatment Diabetic Retinopathy Study logMAR chart. Digital retroillumination images of the posterior capsule were taken with the pupil dilated and analyzed with POCO software. Results: Eyes with the 1CU IOL had significantly higher PCO rates than eyes with the MA30 IOL at all time points. By 2 years after surgery, 50% of eyes with a 1CU IOL had required Nd:YAG capsulotomy compared with no eyes with an MA30 IOL. There was no significant difference in visual acuity at any time point when post Nd:YAG capsulotomy was taken in to account. Conclusions: The 1CU IOL has 4 broad optic-haptic junctions where the square-edged barrier is breached; this appeared to allow passage of lens epithelial cells, leading to an increase in PCO. However, the increased PCO cannot be attributed to this alone as the 1CU is hydrophilic, a factor known to be associated with higher PCO rates.
UR - http://www.scopus.com/inward/record.url?scp=33847148410&partnerID=8YFLogxK
U2 - 10.1016/j.jcrs.2006.10.056
DO - 10.1016/j.jcrs.2006.10.056
M3 - Article
C2 - 17321391
AN - SCOPUS:33847148410
SN - 0886-3350
VL - 33
SP - 413
EP - 417
JO - Journal of Cataract and Refractive Surgery
JF - Journal of Cataract and Refractive Surgery
IS - 3
ER -