TY - JOUR
T1 - Development and validation of a nonaplex assay for the simultaneous quantitation of antibodies to nine Streptococcus pneumoniae serotypes
AU - Lal, Gouri
AU - Balmer, Paul
AU - Stanford, Elaine
AU - Martin, Sarah
AU - Warrington, Rosalind
AU - Borrow, Raymond
PY - 2005/1
Y1 - 2005/1
N2 - Serum IgG levels specific for Streptococcus pneumoniae are currently quantified using the ELISA. However, this method has significant limitations in that a separate test is required for each serotype-specific antibody. Here, we describe a rapid and simple method for the simultaneous quantitation of IgG to nine pneumococcal serotypes (1, 4, 5, 6B, 9V, 14, 18C, 19F, 23F). Pneumococcal polysaccharides were covalently attached to fluorescent microspheres and these beads were serologically assessed using 89-SF standard serum. The multiplex assay was linear over a 24-fold serum dilution range and comparison of monoplex and nonaplex assays revealed no evidence of bead interference. The nonaplex assay was shown to be specific with <30% heterologous inhibition occurring and assay sensitivity was high with the LOD ranging between 32.3 and 109.7 pg/ml. The assay was shown to have low inter- and intra-assay variability and conjugated microspheres were shown to remain stable over 12 months. When samples were assayed there was a good correlation of the nonaplex assay with the ELISA. Finally, four bead sets coated with meningococcal polysaccharides (serogroups A, C, Y and W135) were added into the nonaplex assay, with no effect on the pneumococcal or meningococcal IgG levels generated. The pneumococcal nonaplex assay will prove to be a valuable tool to aid in the evaluation of pneumococcal capsular polysaccharide-based vaccines.
AB - Serum IgG levels specific for Streptococcus pneumoniae are currently quantified using the ELISA. However, this method has significant limitations in that a separate test is required for each serotype-specific antibody. Here, we describe a rapid and simple method for the simultaneous quantitation of IgG to nine pneumococcal serotypes (1, 4, 5, 6B, 9V, 14, 18C, 19F, 23F). Pneumococcal polysaccharides were covalently attached to fluorescent microspheres and these beads were serologically assessed using 89-SF standard serum. The multiplex assay was linear over a 24-fold serum dilution range and comparison of monoplex and nonaplex assays revealed no evidence of bead interference. The nonaplex assay was shown to be specific with <30% heterologous inhibition occurring and assay sensitivity was high with the LOD ranging between 32.3 and 109.7 pg/ml. The assay was shown to have low inter- and intra-assay variability and conjugated microspheres were shown to remain stable over 12 months. When samples were assayed there was a good correlation of the nonaplex assay with the ELISA. Finally, four bead sets coated with meningococcal polysaccharides (serogroups A, C, Y and W135) were added into the nonaplex assay, with no effect on the pneumococcal or meningococcal IgG levels generated. The pneumococcal nonaplex assay will prove to be a valuable tool to aid in the evaluation of pneumococcal capsular polysaccharide-based vaccines.
KW - ELISA
KW - Multiplex
KW - Pneumococcal polysaccharide
KW - Pneumococcal vaccine
UR - http://www.scopus.com/inward/record.url?scp=12944278736&partnerID=8YFLogxK
U2 - 10.1016/j.jim.2004.11.006
DO - 10.1016/j.jim.2004.11.006
M3 - Article
C2 - 15680158
AN - SCOPUS:12944278736
SN - 0022-1759
VL - 296
SP - 135
EP - 147
JO - Journal of Immunological Methods
JF - Journal of Immunological Methods
IS - 1-2
ER -