Abstract
Purpose: A rapid test for influenza viruses (Binax NOW®) was evaluated. Materials and Methods: In season-1, 35 respiratory samples were tested retrospectively; in season-2, 45 samples were tested prospectively [gold-standard: viral culture in season-1, culture+ reverse transcriptase- polymerase chain reaction (RT-PCR) in season-2]. Results: Sensitivity for Binax for influenza A was 59.3 and 0% in season-1 and -2, respectively. Sensitivity was low for influenza B (33.3% in season-1, 26.1% in season-2). Samples having low viral load were more likely to have a negative Binax test. Specificity of Binax was high (100 and 94.7% with influenza A and B, respectively). Conclusion: Sensitivity information provided in the kit insert does not always reflect post licensure performance in clinical settings.
| Original language | English |
|---|---|
| Pages (from-to) | 19-21 |
| Number of pages | 3 |
| Journal | Indian Journal of Medical Microbiology |
| Volume | 29 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - Jan 2011 |
| Externally published | Yes |
Keywords
- Influenza
- rapid antigen test
- sensitivity
Fingerprint
Dive into the research topics of 'BinaxNOW® - An immunochromatographic test for the diagnosis of human influenza viruses: Comparison with viral culture and polymerase chain reaction'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver